1,103 research outputs found

    Controlling the crystal polymorph by exploiting the time dependence of nucleation rates

    Get PDF
    Most substances can crystallise into two or more different crystal lattices, called polymorphs. Despite this, there are no systems in which we can quantitatively predict the probability of one competing polymorph forming, instead of the other. We address this problem using large scale (hundreds of events) studies of the competing nucleation of the alpha and gamma polymorphs of glycine. In situ Raman spectroscopy is used to identify the polymorph of each crystal. We find that the nucleation kinetics of the two polymorphs is very different. Nucleation of the alpha polymorph starts off slowly but accelerates, while nucleation of the gamma polymorph starts off fast but then slows. We exploit this difference to increase the purity with which we obtain the gamma polymorph by a factor of ten. The statistics of the nucleation of crystals is analogous to that of human mortality, and using a result from medical statistics we show that conventional nucleation data can say nothing about what, if any, are the correlations between competing nucleation processes. Thus we can show that, with data of our form, it is impossible to disentangle the competing nucleation processes. We also find that the growth rate and the shape of a crystal depends on when it nucleated. This is new evidence that nucleation and growth are linked.Comment: 8 pages, plus 17 pages of supplementary materia

    Condition monitoring of rotating machinery - vibration analysis

    Get PDF
    The aim of condition monitoring is to detect defective machine components and allow timely repair before failure and secondary damage occurs. This project, in particular, covers the condition monitoring techniques applicable to rotating machinery and vibration analysis. Vibration analysis is a specialised role and equipment owners often have a limited under- standing of it. Practicing technicians also benefit from better understanding fundamental principles and ongoing training. Key to improving outcomes of CM programs is improving knowledge and understanding. Utilising overall project specifications, a schedule, flow and Gantt charts, decision trees, listing activities with diagrams and milestones ensured the orderly development of the project. Researching condition monitoring practices and standards applicable to rotating machinery led to developing required outcomes, software specifications and user requirements for a virtual training package prior to writing the Matlab program. Development of the vibration training program in line with ISO18436-2 requirements and industry recognised practices for personnel conducting and utilising vibration condition monitoring resulted in a program that is easy to use, familiarising the user with fundamental concepts and readily detectable faults. The key aspect of the project, the development of a training and awareness tool based on industry practices and expectations, is displayed in the training program. It is a tool that can help technicians and plant owners better understand and implement vibration condition monitoring and improve outcomes thus reducing costly unplanned plant outages

    Evidence of package trading in a mature multi-species ITQ market

    Get PDF
    In multi-species fisheries managed under ITQs, the existence of joint production may lead to complex catch-quota balancing issues. Previous modelling and experimental research suggest that, in such fisheries, some fishers may benefit from the ability to trade packages of fishing quotas, rather than fulfil their quota needs by simultaneously bidding on separate single-species quota markets. This note presents evidence of naturally occurring package trades in a real fishery. Based on this evidence, we suggest that further empirical and modelling research is required on the potential and limitations of package quota trading in mixed fisheries managed with ITQs. © 2014

    Minor histocompatibility antigen-specific cytotoxic T lymphocytes generated with dendritic cells from DLA-identical littermates

    Get PDF
    AbstractDonor cytotoxic T lymphocytes (CTL) specific for minor histocompatibility antigens (mHA) mediate the graft-versus-host effect whereas host mHA-specific CTL mediate graft rejection in the setting of major histocompatibility complex identical allogeneic hematopoietic stem cell transplantation. Development of a large animal model from which mHA-specific CTL can be isolated would accelerate translation in clinical studies to improve control of the graft-versus-host effect as well as prevention of graft rejection in sensitized hosts. The aims of the current study were to isolate mHA-specific CTL from dog leukocyte antigen-identical littermate nonsensitized recipients before transplantation, from stable mixed hematopoietic chimeras, and from dogs sensitized to mHA after graft rejection. Donor dendritic cells (DCs) were cultured from bone marrow-derived CD34+ cells and were used to stimulate recipient T lymphocytes on days 1, 10, and 20 of CTL culture. We reliably generated and expanded mHA-specific CTL ex vivo from sensitized dogs that were given a donor-specific blood transfusion to boost immune recall after graft rejection after a nonmyeloablative transplantation. The mHA-specific cytotoxicity measured by 51Cr release assay was enriched from less than 5% in the starting population of sensitized peripheral blood mononuclear cells to a median of 63% after 4 weeks in CTL culture. The expanded mHA-specific CTLs were not tissue-specific: hematopoietic cells, fibroblast, and stromal cell lines were lysed in an mHA-specific manner. Allogeneic DCs, but not peripheral blood mononuclear cells, were necessary for stimulating ex vivo expansion of mHA-specific CTL. We were unable to generate mHA-specific CTL from nonsensitized dogs before transplantation, from previously sensitized dogs but without recent recall immunization, or from stable mixed hematopoietic chimeras. We conclude that after recent in vivo sensitization, large-scale ex vivo expansion of mHA-specific CTL was feasible using allogeneic DCs. © 2003 American Society for Blood and Marrow TransplantationBiology of Blood and Marrow Transplantation 9:234-242 (2003

    Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction

    Get PDF
    To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d°) and at a distance (dâ€Č) from the collimator. A simple geometric attenuation correction was performed to obtain absolute left ventricular volume estimates.Using blood sample counts obtained at d° or dâ€Č, the attentuation.corrected radionuclide left ventricular end-diastolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-diastolic volumes (r = 0.95 to 0.96). However, both mean radionuclide semiautomated variable left ventricular end-diastolic volumes (179 ± 100 [± 1 standard deviation] and 185 ± 102 ml, p < 0.001) were smaller than the average cineangiographic end-diastolic volume (217 ± 102 ml), and both mean hand-drawn left ventricular end-diastolic volumes (212 ± 104 and 220 ± 106 ml) did not differ from the average cineangiographic end-diastolic volume. Using the blood sample counts obtained at d° or dâ€Č, the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d°, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 ± 98 ml, p < 0.05) was less than the average cineangiographic end-systolic volume (128 ± 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume.Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator

    Sustainable intensification of aquaculture value chains between Asia and Europe: A framework for understanding impacts and challenges

    Get PDF
    Sustainable intensification (SI) is defined and interpreted in terms of a framework to support production of farmed aquatic animals in Asia and their trade with Europe. A novel holistic perspective to value chain analysis, informed by a range of sustainability tools, is used to explain the dynamic in the trade that is having significant impacts on livelihoods in both regions. The origins of SI in agriculture are first described and their congruence with aquaculture clarified. Asian aquaculture systems, based on their emergent properties, are then located within a SI framework considering possible boundaries (enterprise, zone or whole value chain). The implications of conventional intensification, and alternatives are explored with reference to specific examples and impacts on the local and global environment, human and aquatic animal health and welfare. The challenges to sustainability of such value chains and implications for their governance, food culture and consumer habits are considered. Local consumption of seafood in Asia is found to be a major driver of growth and alternative markets for exports regionally and in Low and Medium income countries (LMIC) are likely to impact on employment and power in the value chain between Europe and Asia. The benefits of viewing farmed seafood as part of broader food landscapes are identified in the analysis, as is a shift in the focus from volume to value in terms of goal setting. More holistic perspectives of sustainability also emerge as necessary to describe and interpret global value chains rather than limited reductionist, production- orientated views. A diversity of trends in the development of farmed seafood is identified in contrast to any simplistic move to intensification, likely informed by economic, environmental and social factors in producer and consumer countries.  Statement of relevance  Global imbalances in production and consumption of farmed seafood are stimulating trade between Asia and Europe. The dynamic of global value chains around this emergent trade and their alignment with broader sustainability criteria, as applied to sustainable intensification of food production, are highly relevant to global food security

    Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction

    Get PDF
    To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d°) and at a distance (dâ€Č) from the collimator. A simple geometric attenuation correction was performed to obtain absolute left ventricular volume estimates.Using blood sample counts obtained at d° or dâ€Č, the attentuation.corrected radionuclide left ventricular end-diastolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-diastolic volumes (r = 0.95 to 0.96). However, both mean radionuclide semiautomated variable left ventricular end-diastolic volumes (179 ± 100 [± 1 standard deviation] and 185 ± 102 ml, p < 0.001) were smaller than the average cineangiographic end-diastolic volume (217 ± 102 ml), and both mean hand-drawn left ventricular end-diastolic volumes (212 ± 104 and 220 ± 106 ml) did not differ from the average cineangiographic end-diastolic volume. Using the blood sample counts obtained at d° or dâ€Č, the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d°, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 ± 98 ml, p < 0.05) was less than the average cineangiographic end-systolic volume (128 ± 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume.Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator

    WKY Fatty Rat as a Model of Obesity and Non-insulin-dependent Diabetes Mellitus

    Get PDF
    This article is made available for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic

    Randomised controlled feasibility trial of a web-based weight management intervention with nurse support for obese patients in primary care

    Get PDF
    &lt;b&gt;Background&lt;/b&gt;&lt;p&gt;&lt;/p&gt; There is a need for cost-effective weight management interventions that primary care can deliver to reduce the morbidity caused by obesity. Automated web-based interventions might provide a solution, but evidence suggests that they may be ineffective without additional human support. The main aim of this study was to carry out a feasibility trial of a web-based weight management intervention in primary care, comparing different levels of nurse support, to determine the optimal combination of web-based and personal support to be tested in a full trial.&lt;p&gt;&lt;/p&gt; &lt;b&gt;Methods&lt;/b&gt;&lt;p&gt;&lt;/p&gt; This was an individually randomised four arm parallel non-blinded trial, recruiting obese patients in primary care. Following online registration, patients were randomly allocated by the automated intervention to either usual care, the web-based intervention only, or the web-based intervention with either basic nurse support (3 sessions in 3 months) or regular nurse support (7 sessions in 6 months). The main outcome measure (intended as the primary outcome for the main trial) was weight loss in kg at 12 months. As this was a feasibility trial no statistical analyses were carried out, but we present means, confidence intervals and effect sizes for weight loss in each group, uptake and retention, and completion of intervention components and outcome measures.&lt;p&gt;&lt;/p&gt; &lt;b&gt;Results&lt;/b&gt;&lt;p&gt;&lt;/p&gt; All randomised patients were included in the weight loss analyses (using Last Observation Carried Forward). At 12 months mean weight loss was: usual care group (n = 43) 2.44 kg; web-based only group (n = 45) 2.30 kg; basic nurse support group (n = 44) 4.31 kg; regular nurse support group (n = 47) 2.50 kg. Intervention effect sizes compared with usual care were: d = 0.01 web-based; d = 0.34 basic nurse support; d = 0.02 regular nurse support. Two practices deviated from protocol by providing considerable weight management support to their usual care patients.&lt;p&gt;&lt;/p&gt; &lt;b&gt;Conclusions&lt;/b&gt;&lt;p&gt;&lt;/p&gt; This study demonstrated the feasibility of delivering a web-based weight management intervention supported by practice nurses in primary care, and suggests that the combination of the web-based intervention with basic nurse support could provide an effective solution to weight management support in a primary care context

    Detection of CI in absorption towards PKS 1830-211 with the eSMA

    Get PDF
    We report the first science observations and results obtained with the "extended" SMA (eSMA), which is composed of the SMA (Submillimeter Array), JCMT (James Clerk Maxwell Telescope) and CSO (Caltech Submillimeter Observatory). Redshifted absorptions at z=0.886 of CI (^3P_1 - ^3P_0) were observed with the eSMA with an angular resolution of 0.55"x0.22" at 1.1 mm toward the southwestern image of the remarkable lensed quasar PKS 1830-211, but not toward the northeastern component at a separation of ~1". Additionally, SMA observations of CO, 13CO and C18O (all J=4-3) were obtained toward this object: CO was also detected toward the SW component, but none of the isotopologues were. This is the first time [CI] is detected in this object, allowing the first direct determination of relative abundances of neutral atomic carbon to CO in the molecular clouds of a spiral galaxy at z>0.1. The [CI] and CO profiles can be decomposed into two and three velocity components respectively. We derive C/CO column density ratios ranging from <0.5 (representative of dense cores) to ~2.5 (close to translucent clouds values). This could indicate that we are seeing environments with different physical conditions or that we are witnessing chemical evolution of regions where C has not completely been converted into CO.Comment: 6 pages using emulateapj, 3 tables, 2 figures ; accepted for publication in ApJ
    • 

    corecore